產(chǎn)品概述Product Brief
The static reactive power generator SVG adopts a power-electronic device (IGBT) that can be turned off to form a self-commutated bridge circuit, connected in parallel to the power grid through a reactor, and appropriately adjusts the amplitude and phase of the output voltage of the AC side of the bridge circuit, or directly Control its AC side current. Quickly absorb or emit the required reactive power to achieve the purpose of quickly and dynamically adjusting reactive power. As an active compensation device, it can not only track the inrush current of the impact load, but also track and compensate the harmonic current.
靜止無功發(fā)生器SVG采用可關斷電力電子器件(IGBT)組成自換相橋式電路,經(jīng)過電抗器并聯(lián)在電網(wǎng)上,適當?shù)卣{(diào)節(jié)橋式電路交流側輸出電壓的幅值和相位,或者直接控制其交流側電流。迅速吸收或者發(fā)出所需的無功功率,實現(xiàn)快速動態(tài)調(diào)節(jié)無功的目的。作為有源型補償裝置,不僅可以跟蹤沖擊型負載的沖擊電流,而且可以對諧波電流也進行跟蹤補償。
混合補償SVGC示意圖Schematic diagram of mixed compensation SVGC
注Note:
無源單組的補償容量一定要小于有源的補償容量,才可達到細補的要求。
The compensation capacity of the passive single group must be smaller than the active compensation capacity to meet the requirements of fine compensation.
技術參數(shù)表Technical Data Sheet
過載能力 | Overload capacity | 120%,1min,110%長期運行,120%短期運行(0.5h-1h) |
冷卻方式 | cooling method | 強迫風冷 |
通訊接口 | Communication Interface | RS232/Modbus |
噪音水平 | Noise level | <65dB@1m |
無功補償能力 | Reactive power compensation ability | -1~1 |
功能設置 | Function settings | SVG、TSVG |
海拔高度 | Altitude | 2000米/最高4000米,1%/100米降容 |
響應時間 | Response time | 暫態(tài)響應時間300us,全響應時間10ms |
電流互感器 | Current Transformer | 300:5到50000:5(可靈活設置)開環(huán)連接 |
電路拓撲 | Circuit topology | 三電平 |
通訊接口 | Communication Interface | RS485,網(wǎng)口 |
通訊協(xié)議 | Protocol | 電總協(xié)議,Modbus協(xié)議、TCP/IP、DTU/FTU |
快速響應時間 | Fast response time | <50μs |
全響應時間 | Full response time | <5ms |
開關頻率 | On-off level | 30kHz |
保護功能 | Protective function | 過壓保護、欠壓保護、短路保護、過補償保護 |
故障報警 | error alarm | 500條 |
監(jiān)控 | monitor | 獨立/集中監(jiān)控 |
顯示屏 | Display | 彩色觸摸屏 |
安裝方式 | Installation method | 機架式/壁掛式 |
防護等級 | Protection level | IP20可定制 |
電網(wǎng)頻率 | Grid frequency | 50Hz/60Hz |
遵循標準 | Follow the standard | IEEE519\IEC 61000-3-6,ER G5/4 |
資質(zhì)認證 | Certification | CQC認可實驗室型式試驗報告 |
常用規(guī)格&產(chǎn)品尺寸Common specifications & product size
各型號具體外形尺寸定義見下圖,詳細尺寸見下表。
See the following figure for the definition of specific external dimensions of each model, and the following table for detailed dimensions.
模塊外形尺寸定義
Order code 訂購代碼 | Module capacity 模塊容量/kvar | System voltage 系統(tǒng)電壓/V | W 寬/mm | D 深/mm | H 高/mm | Weight 重量/kg |
IVD-SVG35 | 35 | 208~690 | 375 | 550 | 170 | 20 |
IVD-SVG50 | 50 | 208~690 | 500 | 550 | 200 | 35 |
IVD-SVG75 | 75 | 208~690 | 500 | 580 | 240 | 40 |
IVD-SVG100 | 100 | 208~690 | 500 | 650 | 270 | 50 |
IVD-SVG150 | 150 | 208~690 | 500 | 650 | 270 | 60 |
★以上僅列出常用型號,其他規(guī)格請洽本公司。
無功補償容量選型:一般按照變壓器容量的30%進行選型,例如變壓器容量為1250KVA,則需要配備375Kvar的無功補償,混補模式可配備75Kvar有源+300Kvar的無源(注:無源每組的補償容量一定要小于有源的補償容量,才可達到細補的要求。)
Reactive compensation capacity selection: Generally, the selection is based on 30% of the transformer capacity. For example, the transformer capacity is 1250KVA, then 375Kvar reactive power compensation is required, and the mixed compensation mode can be equipped with 75Kvar active + 300Kvar passive (Note: None The compensation capacity of each source group must be smaller than the active compensation capacity to meet the requirements of fine compensation.)