產(chǎn)品概述Product Brief

The static reactive power generator SVG adopts a power-electronic device (IGBT) that can be turned off to form a self-commutated bridge circuit, connected in parallel to the power grid through a reactor, and appropriately adjusts the amplitude and phase of the output voltage of the AC side of the bridge circuit, or directly Control its AC side current. Quickly absorb or emit the required reactive power to achieve the purpose of quickly and dynamically adjusting reactive power. As an active compensation device, it can not only track the inrush current of the impact load, but also track and compensate the harmonic current.

靜止無功發(fā)生器SVG采用可關斷電力電子器件(IGBT)組成自換相橋式電路,經(jīng)過電抗器并聯(lián)在電網(wǎng)上,適當?shù)卣{(diào)節(jié)橋式電路交流側輸出電壓的幅值和相位,或者直接控制其交流側電流。迅速吸收或者發(fā)出所需的無功功率,實現(xiàn)快速動態(tài)調(diào)節(jié)無功的目的。作為有源型補償裝置,不僅可以跟蹤沖擊型負載的沖擊電流,而且可以對諧波電流也進行跟蹤補償。

IVD-SVG靜止無功發(fā)生器

混合補償SVGC示意圖Schematic diagram of mixed compensation SVGC

IVD-SVG靜止無功發(fā)生器

注Note:

無源單組的補償容量一定要小于有源的補償容量,才可達到細補的要求。

The compensation capacity of the passive single group must be smaller than the active compensation capacity to meet the requirements of fine compensation.

 


 

技術參數(shù)表Technical Data Sheet

過載能力

Overload capacity

120%,1min,110%長期運行,120%短期運行(0.5h-1h)

冷卻方式

cooling method

強迫風冷

通訊接口

Communication Interface

RS232/Modbus

噪音水平

Noise level

<65dB@1m

無功補償能力

Reactive power compensation ability

-1~1

功能設置

Function settings

SVG、TSVG

海拔高度

Altitude

2000米/最高4000米,1%/100米降容

響應時間

Response time

暫態(tài)響應時間300us,全響應時間10ms

電流互感器

Current Transformer

300:5到50000:5(可靈活設置)開環(huán)連接

電路拓撲

Circuit topology

三電平

通訊接口

Communication Interface

RS485,網(wǎng)口

通訊協(xié)議

Protocol

電總協(xié)議,Modbus協(xié)議、TCP/IP、DTU/FTU

快速響應時間

Fast response time

<50μs

全響應時間

Full response time

<5ms

開關頻率

On-off level

30kHz

保護功能

Protective function

過壓保護、欠壓保護、短路保護、過補償保護

故障報警

error alarm

500條

監(jiān)控

monitor

獨立/集中監(jiān)控

顯示屏

Display

彩色觸摸屏

安裝方式

Installation method

機架式/壁掛式

防護等級

Protection level

IP20可定制

電網(wǎng)頻率

Grid frequency

50Hz/60Hz

遵循標準

Follow the standard

IEEE519\IEC 61000-3-6,ER G5/4

資質(zhì)認證

Certification

CQC認可實驗室型式試驗報告

 


 

常用規(guī)格&產(chǎn)品尺寸Common specifications & product size

各型號具體外形尺寸定義見下圖,詳細尺寸見下表。

See the following figure for the definition of specific external dimensions of each model, and the following table for detailed dimensions.

IVD-SVG靜止無功發(fā)生器

模塊外形尺寸定義

Order code

訂購代碼

Module capacity

模塊容量/kvar

System voltage

系統(tǒng)電壓/V

W

寬/mm

D

深/mm

H

高/mm

Weight

重量/kg

IVD-SVG35

35

208~690

375

550

170

20

IVD-SVG50

50

208~690

500

550

200

35

IVD-SVG75

75

208~690

500

580

240

40

IVD-SVG100

100

208~690

500

650

270

50

IVD-SVG150

150

208~690

500

650

270

60

★以上僅列出常用型號,其他規(guī)格請洽本公司。

 無功補償容量選型:一般按照變壓器容量的30%進行選型,例如變壓器容量為1250KVA,則需要配備375Kvar的無功補償,混補模式可配備75Kvar有源+300Kvar的無源(注:無源每組的補償容量一定要小于有源的補償容量,才可達到細補的要求。)

Reactive compensation capacity selection: Generally, the selection is based on 30% of the transformer capacity. For example, the transformer capacity is 1250KVA, then 375Kvar reactive power compensation is required, and the mixed compensation mode can be equipped with 75Kvar active + 300Kvar passive (Note: None The compensation capacity of each source group must be smaller than the active compensation capacity to meet the requirements of fine compensation.)